Power Capacitor Turn On/Off & Motor Switch On/Off (High Voltage SSRs)
Type | Features | Operational Current A | Operating Voltage VAC | Control Voltage VDC | Outline |
---|---|---|---|---|---|
Series SGDH (40~150A) | • AC single phase • SCR output | 40, 60, 80, 100, 120, 150 | 530, 600 | 4~16 | WG30 WG32 |
Series SGDH (200~350A) | • AC single phase • SCR output | 200, 250, 300, 350 | 530, 600 | 4~16 | WG33 |
Series SGTH (40~80A) | • AC three phase • SCR output | 3×40A, 3×60A, 3×80A | 530, 600 | 4~16 | WG35 WG36 |
Power Capacitor Turn On/Off (Compound SSRs)
Type | Features | Operational Current A | Operating Voltage VAC | Control Voltage VDC | Outline |
---|---|---|---|---|---|
Series SGDF (60~80A) | • AC single phase • Bar structure • Dual SCR power hybrid technology • High voltage (1400VPK) versions for 530VRMS service • Switch type: zero voltage turn on, zero current turn off | 60, 80 | 280, 480 | 12 | WG37 |
Series SGDF (120~250A) | 120, 180, 250 | 280, 480 | 12 | WG38 |
For Reversing Motor
Type | Features | Load Power kW | Operating Voltage VAC | Control Voltage | Outline |
---|---|---|---|---|---|
Series SGR (1~7kW) | • Used for 3-phase motor • Built-in interlock function • AC or DC control voltage • Dual SCR power hybrid technology • Switch phases: 2-leg or 3-leg models | 1, 3, 5, 7 | 480, 530 | 10~30VDC
115VAC | WG36 |
For Voltage Regulation
Type | Features | Operational Current A | Operating Voltage VAC | Control Mode | Outline |
---|---|---|---|---|---|
Series SGRV (10~40A) | • Integrated phase control • Control mode: manual • Triac output | 10, 15, 25, 40 | 240 | 330kΩ | WG30 |
Series SGRV (10~120A) | • Integrated phase control • Control mode: automatism or manual • Triac output or SCR output | 10, 15, 25, 40 (for Triac, SCR) | 240, 440 (for Triac)
280, 480 (for SCR) | 0~5VDC or 4~20mA (for automatism) 10kΩ potentionmeter (for manual) | WG39 |
60, 80, 100, 120 (for SCR) |
For Light Regulation
Type | Features | Operational Current A | Operating Voltage VAC | Control Voltage VDC | Outline |
---|---|---|---|---|---|
Series SGDH (40~80A)
| • AC single phase • Anti-electromagnetic interference • Photoelectric couple input • Double SCR reverse-parallel output • 'Vacuum +N2 protection' soldering technology • SMT mounting | 40, 60, 80
| 240 | 3~8 4~16 3~32 |
|
For Oiler
Type | Features | Operational Current A | Operating Voltage VAC | Control Voltage VDC | Outline |
---|---|---|---|---|---|
Series SGS (1~3A) | • AC single phase (SGS); AC three phase (SGT) • Anti-electromagnetic interference • Photoelectric couple input • Triac output | 1, 2, 3
| 240, 440 | 3~8 4~16 | |
Series SGS (10~40A) | 3×10A, 3×15A, 3×25A, 3×40A, | 440 | 3~8 4~16 | WG35 |